-
Measuring principle
Vibration Density
-
Characteristic / Application
Density Computer
Software offers modules for density,
reference density, concentration of liquids
and for a intelligent medium detection -
Supply / Communication
AC 90-253V
DC 20-36V -
Ambient temperature
-20…50°C
-
Output
4-20mA
Profibus DP
Ethernet -
Certificates / Approvals
ATEX
EAC
CSA
IECEx -
Options
Mathscapabilities for further calculations
-
Specialities
Configuration with ReadWin2000
Field of application
The density measuring line can be used in all liquid media for medium detection, to calculate the reference density, to calculate the concentration of a liquid, to convert values to different units such as °Brix, °Baumé, °API etc. Additional software modules, such as determining the reference density, intelligent medium differentiation and concentration identification, support the user in monitoring the quality. EEx ia, EEx de and EEx d explosion protection for use in hazardous areas.
Density computer for density, reference density, concentration of liquids.
-
Ambient temperature: -20 to +50°C (-4 to +122°F)
-
International explosion protection certificates
Benefits
-
Measurement used in tanks and pipes without the need for additional pipework
-
Large number of process connections to choose from: universal usage
-
Integration of existing temperature measurements for temperature compensation
-
No mechanically moving parts: no maintenance, no wear, long operating life
-
pump dry-run protector can be provided with the same process connection
-
Additional calculations, such as the mass of the product, can be performed in the Density Computer FML621
-
The integrated data logger supports users during operation and servicing