Max. measurement error
Volume flow:
– ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
– ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
Measuring range
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
Medium temperature range
0 to 150° (17.8 to 302 °F)
Max. process pressure
PN 25 / ASME Cl. 150
Wetted materials
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105