Specs at a glance
-
Process temperature
-50 °C…+150 °C
(-58 °F…+302 °F) -
Process pressure / max. overpressure limit
Vacuum…64 bar
(Vacuum…928 psi) -
Min. density of medium
0.5g/cm³
(0.4g/cm³ optional)
Field of application
Liquiphant FTL50H is a point level switch for use in hazardous areas with all international certificates. Especially useable in the food and life sciences industry with hygienic certificates (3-A, EHEDG, ASME BPE). FTL50H offers functional safety SIL2/SIL3. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for all liquids with completely welded housing concept.
-
Process connections: Threads, flanges and hygienic process connection (Tri-Clamp, dairy coupling, aseptic, DRD, SMS, Varivent)
-
Temperature: -50 to +150°C (-58 to +302°F)
-
Pressure: -1 to +64bar (-14.5 to +928psi)
-
Sensor material: 316L
-
International explosion protection certificates, overfill protection WHG, SIL, hygienic certificates, marine approvals
Benefits
-
International hygienic certificates (3-A, EHEDG, ASME BPE). FDA-conformed material
-
Electro-polished and passivated surface finishing
-
International explosion protection certificates and overfill protection certificate (WHG)
-
No mechanically moving parts: no maintenance, no wear, long operating life.
Monitoring of fork for damage: guaranteed function -
Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with
IEC 61508/IEC 61511-1 -
No calibration required, easy to start up
-
Variety of standardized hygienic process connections for hygiene sensitive applications