Characteristic
The position of the switching point can be up to 6 m away from the installation site. Numerous process fittings, approvals as well as housing and electronics versions.
Application
VEGASWING 63 is used as a universal level switch in all liquids. Independent of the mounting position it detects reliably with millimetre accuracy the level. The instrument can be used in vessels as empty or full detector, as approved overfill protection, dry run protection or pump protection. The position of the switching point is determined through the tube extension. The VEGASWING 63 offers high reliability and security in a wide application range.
Benefits
- Precise and reliable function due to product-independent switching point
- Low maintenance costs
- Minimum time and cost expenditure thanks to simple setup without medium
Technical Data
| Process temperature | -50 … 250 °C |
| Process pressure | -1 … 64 bar |
| Version | Standard Hygienic applications with gas-tight leadthrough with tube extension with temperature adapter |
| Materials, wetted parts | PFA 316L Alloy C22 (2.4602) Alloy 400 (2.4360) ECTFE Enamel |
| Threaded connection | ≥ G¾, ≥ ¾ NPT |
| Flange connection | ≥ DN25, ≥ 1″ |
| Hygenic fittings | Clamp ≥ 1″ – DIN32676, ISO2852 Slotted nut ≥ 1½”, ≥ DN40 – DIN 11851 Varivent ≥ DN25 hygienic fitting F40 with compression nut SMS 1145 DN51 SMS DN38 Hygienic fittings ≥ DN25 – DIN11864-1-A Hygienic flange connection DIN11864-2-A; DN60(ISO)ø60,3 SMS socket piece DN38 PN6 |
| Seal material | no media contact |
| Housing material | Plastic Aluminium Stainless steel (precision casting) Stainless steel (electropolished) |
| Protection rating | IP66/IP67 IP66/IP68 (1 bar) IP65 |
| Output | Relay (DPDT) Contactless electronic switch Transistor (NPN/PNP) Two-wire NAMUR |
| Ambient temperature | -40 … 70 °C |
| Scope | ATEX / Europe CSA / Canada FM / USA EAC (GOST) / Belarus EAC (GOST) / Kazakhstan EAC (GOST) / Russia IEC / worldwide KOSHA / Korea NEPSI / China UKR Sepro / Ukraine INMETRO / Brazil CCOE / India |
| Explosion protection | Intrinsic safety “i” Flameproof enclosure “d” Dust ignition protection “t” |
| Foodstuffs/Pharma | 3A EHEDG FDA |
| Ship approval | ABS BV CCS DNV GL LR RINA RMROS |
| Overfill protection | WHG VLAREM II |
| SIL qualification | SIL2 |
| Indication | Pluggable display module PLICSLED |