Characteristic
Cable, rod or coaxial sensor. Even in applications with steam, buildup, foam or condensation, the sensor delivers precise and reliable readings – also in standpipes or bypass pipes.
Application
The VEGAFLEX 81 level sensor measures maintenance-free all kind of liquids. Even in applications with vapour, buildup, foam generation and condensation, the sensor delivers precise and reliable measured values. The VEGAFLEX 81 is the economical solution for various level and interface measurements.
Benefits
- The guided adjustment enables a simple, time-saving and reliable setup
- Shortenable probes offer a simple standardisation and highest flexibility in the planning
- Comprehensive diagnostic possibilities ensure a maintenance-free operation and hence a high plant availability
Technical Data
| Measuring range – Distance | 75 m |
| Process temperature | -60 … 200 °C |
| Process pressure | -1 … 40 bar |
| Accuracy | ± 2 mm |
| Version | Basic version for exchangeable cable ø 2; ø 4 mm Basic version for exchangeable rod ø 8 mm Basic version for exchangeable rod ø 12 mm Coax version ø 21.3 mm for ammonia application Coax version ø 21.3 mm with single hole Coax version ø 21.3 mm with multiple hole Coax version ø 42.2 mm with multiple hole Exchangeable rod ø 8 mm Exchangeable rod ø 12 mm Exchangeable cable ø 2 mm with gravity weight Exchangeable cable ø 4 mm with gravity weight Exchangeable cable ø 2 mm with centering weight Exchangeable cable ø 4 mm with centering weight Exchangeable cable ø 4 mm without weight exchangeable, PFA-coated cable ø4 mm with non-coated centering weight |
| Materials, wetted parts | PFA 316L Alloy C22 (2.4602) Alloy 400 (2.4360) Alloy C276 (2.4819) Duplex (1.4462) 304L |
| Threaded connection | ≥ G¾, ≥ ¾ NPT |
| Flange connection | ≥ DN25, ≥ 1″ |
| Seal material | EPDM FKM FFKM Silicone FEP coated Borosilicate glass |
| Housing material | Plastic Aluminium Stainless steel (precision casting) Stainless steel (electropolished) |
| Protection rating | IP66/IP68 (0,2 bar) IP66/IP67 IP66/IP68 (1 bar) |
| Output | Profibus PA Foundation Fieldbus Two-wire: 4 … 20 mA/HART Modbus Four-wire: 4 … 20 mA/HART |
| Ambient temperature | -40 … 80 °C |
| Scope | ATEX / Europe CSA / Canada FM / USA EAC (GOST) / Belarus EAC (GOST) / Kazakhstan EAC (GOST) / Russia IEC / worldwide NEPSI / China UKR Sepro / Ukraine INMETRO / Brazil CCOE / India KTL Korea UKEX |
| Explosion protection | Intrinsic safety “i” Flameproof enclosure “d” Dust ignition protection “t” |
| Foodstuffs/Pharma | FDA |
| Ship approval | ABS BV CCS DNV LR NK RINA |
| Overfill protection | WHG VLAREM II |
| SIL qualification | SIL2 |
| Adjustment | PLICSCOM PC, PACTware and DTM HART-Communicator Software (e. g. AMS™, PDM) |
| Indication | Display/adjustment module PLICSCOM VEGADIS 81 VEGADIS 82 |