- Rugged industrial standard encoder
- Protection to IP67, shaft sealed to IP65
- Maximum mechanical and electrical safety
- Optional:
-40 °C up to +85 °C [-40 °F up to 185 °F],
Protection to IP67 all around,
Pressure equalising membrane
stainless steel
Advice: Attention: No option AAO = full IP67 version
Shaft length: L: 12 mm [0.472″]
Max. Permissible shaft loading radial: 125 N [12.746 kp]
Max. Permissible shaft loading axial: 120 N [12.236 kp]
Advice: Attention: No option AAO = full IP67 version
Shaft length: L: 19 mm [0.748″]
Max. Permissible shaft loading radial: 125 N [12.746 kp]
Max. Permissible shaft loading axial: 120 N [12.236 kp]
Advice: Attention: No option AAO = full IP67 version
Shaft length: L: 20 mm [0.787″]
Max. Permissible shaft loading radial: 220 N [22.433 kp]
Max. Permissible shaft loading axial: 120 N [12.236 kp]
Shaft length: L: 20 mm [0.787″]
Max. Permissible shaft loading radial: 220 N [22.433 kp]
Max. Permissible shaft loading axial: 120 N [12.236 kp]
Current consumption: typ. 40 mA
Environmental data
ESD (DIN EN 61000-4-2):
8 kV
Burst (DIN EN 61000-4-4):
2 kV
includes EMC:
DIN EN 61000-6-2
DIN EN 61000-6-3
Vibration:
(DIN EN 60068-2-6)
50 m/s2 (10 Hz up to 2000 Hz)
Shock:
(DIN EN 60068-2-27)
1000 m/s2 (6 ms)
Electrial Safety:
according DIN VDE 0160
Duty information
Customs tariff number:
90318020
Country of origin:
Germany