Key Specifications
-
Accuracy
±6 mm (0.24 inches)
-
Operating Temperature
-40…+150 °C
(-40…+302 °F) -
Operating Pressure / Max. Overpressure Limit
Vacuum…40 bar
(Vacuum…580 psi) -
Maximum Measuring Distance
Standard: 20 m (66 feet)
-
Primary Wetted Parts
PTFE, PVDF
Application Area
The Micropilot FMR53 is designed for straightforward liquid level measurement tasks. Its compact rod antenna makes the FMR53 radar ideal for small process connections. The PTFE-coated antenna and flanges ensure resistance to aggressive media. The device is used for continuous, non-contact measurement of liquids, pastes, and slurries. Measurement accuracy remains unaffected by environmental changes, temperature fluctuations, gas layers, or vapors.
Optimized for small connections, PTFE sensors resist chemically aggressive environments.
-
Process connections: Thread or flange
-
Temperature range: -40…+150°C (–40…+302°F)
-
Pressure range: -1…+40 bar (–14.5…+580 psi)
-
Maximum measuring range: 20 m (66 feet)
-
Accuracy: ±6 mm
-
C-band frequency: 6 GHz
-
International explosion protection certifications, WHG overfill protection, SIL, 5-point linearity protocol
Advantages
-
Reliable non-contact measurements even with changing process conditions
-
HistoROM data management concept for quick commissioning and diagnostics
-
High reliability despite obstacles thanks to Multi-Echo Tracking technology
-
Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
-
Heartbeat Technology for cost-effective and safe operation throughout the lifecycle
-
Easy connection to control systems with intuitive menu (on-site or via control system)
-
Simplest verification concept for SIL and WHG, saving time and costs