Specs at a glance
-
Max. measurement error
Volume flow (standard):
– ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
– ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) -
Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
-
Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional -
Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
-
Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Field of application
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
-
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
-
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
-
Full compliance according to NACE MR0175 and MR0103
-
Nominal diameter: DN 25 to 300 (1 to 12″)
-
Medium temperature: –40 to 200 °C (–40 to 392 °F)
-
Device as compact or remote version
-
2-line backlit display with push buttons
-
HART, PROFIBUS PA, FOUNDATION Fieldbus
Benefits
-
Safe design for process industries – international hazardous area approvals
-
No additional pressure loss – full-bore design
-
Process transparency – diagnostic capability
-
Easy installation and reduced installation costs – loop-powered transmitter
-
Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
-
Automatic recovery of data for servicing