Key Specifications
-
Maximum measurement accuracy
Liquid mass flow: ±0.10 %
Liquid volume flow: ±0.10 %
Liquid density: ±0.0005 g/cm³ -
Operational range
0 to 70,000 kg/h (0 to 2570 lb/min)
-
Temperature range
–50 to +150 °C (–58 to +302 °F)
-
Maximum working pressure
PN 40, Class 150, 20K
-
Contact materials
Measurement tube: 1.4435 (316L)
Connections: 1.4435 (316L); 1.4404 (316/316L)
Application Areas
The Promass S sets the standard for hygienic design – Endress+Hauser’s industry-specific measurement solution complies with all hygienic requirements for Food and Beverage installations. Featuring the most compact transmitter housing on the market, it delivers maximum performance with minimal space requirements. Engineered for space-constrained applications, the Promass S 100 is the ideal solution for system integrators, skid builders, and equipment manufacturers.
-
Measurement principle unaffected by fluid characteristics like viscosity or density
-
Specifically designed for applications demanding superior cleanability in hygienic environments
Key Features
-
Comprehensive selection of hygienic process connections
-
Compliant with 3-A and EHEDG standards
-
Rapid recovery after CIP/SIP processes
-
Durable, space-efficient transmitter housing
-
Exceptional protection rating: IP69K
-
Optional local display
Advantages
-
Lower installation expenses – self-draining tube design allows for compact horizontal installation
-
Reduced measurement points – simultaneous monitoring of flow, density, and temperature
-
Minimal space requirements – no need for inlet/outlet runs
-
Compact transmitter – full functionality in minimal space
-
Efficient local operation – built-in web server eliminates need for additional tools
-
Built-in verification – Heartbeat Technology