Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)
Field of application
The chemically resistant single-tube design of the Promass H is destined for applications requiring highest corrosion resistance. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications where space is a premium, Promass H 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.
-
Measuring principle operates independently of physical fluid properties such as viscosity or density
-
Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
Device properties
-
Measuring tube made of Tantalum, Zirconium
-
Nominal diameter: DN 8 to 50 (3/8 to 2″)
-
Medium temperature up to +205 °C (+401 °F)
-
Robust, ultra-compact transmitter housing
-
High ingress protection: IP69K
-
Local display available
Benefits
-
Maximum safety for chemically aggressive fluids – corrosion-resistant wetted parts
-
Fewer process measuring points – multivariable measurement (flow, density, temperature)
-
Space-saving installation – no in/outlet run needs
-
Space-saving transmitter – full functionality on the smallest footprint
-
Time-saving local operation without additional software and hardware – integrated web server
-
Integrated verification – Heartbeat Technology