Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +240 °C (–58…+464 °F) -
Max. process pressure
PN 100, Class 600, 63K
-
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Field of application
Promass F has a long standing reputation as a highly accurate device under varying process conditions. It is suited for broadest range of applications. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Promass F 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers. Available with an extra-compact stainless steel hygienic housing it can be placed even into the most compact rigs.
-
Measuring principle operates independently of physical fluid properties such as viscosity or density
-
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Device properties
-
Mass flow: measured error ±0,05 % (PremiumCal)
-
Rated secondary containment up to 40 bar (580 psi)
-
Nominal diameter: DN 8 to 250 (3/8 to 10″)
-
Robust, ultra-compact transmitter housing
-
High ingress protection: IP69K
-
Local display available
Benefits
-
Highest process safety – immune to fluctuating and harsh environments
-
Fewer process measuring points – multivariable measurement (flow, density, temperature)
-
Space-saving installation – no in/outlet run needs
-
Space-saving transmitter – full functionality on smallest footprint
-
Time-saving local operation without additional software and hardware – integrated web server
-
Integrated verification – Heartbeat Technology