Specs at a glance
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)
-
Medium temperature range
–20 to +150 °C (–4 to +302 °F)
-
Max. process pressure
PN 40, Class 150, 20K
-
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: aseptic molded seal (EPDM, FKM, silicone)
Field of application
Promag H is the preferred sensor for hygienic applications in the food and beverage and life sciences industries. With its straightforward hard- and software design, Promag H 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
-
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
-
For applications with sanitary requirements
Device properties
-
Liner made of PFA
-
Sensor housing made of stainless steel (3-A, EHEDG)
-
Wetted materials CIP-/SIP-cleanable
-
System integration with HART, Modbus RS485, IO-Link
-
Flexible operation with app and optional display
Benefits
-
Easy integration into your plant infrastructure with IO-link
-
Flexible installation concept – numerous hygienic process connections
-
Energy-saving flow measurement – no pressure loss due to cross section constriction
-
Maintenance-free – no moving parts
-
Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app
-
Simple, time-saving commissioning – guided parameterization in advance and in the field
-
Integrated verification – Heartbeat Technology