Characteristic
Reliable measurement of highly corrosive and hot media. Can be combined with any other sensor of VEGABAR Series 80 for electronic differential pressure measurement.
Application
The VEGABAR 81 is a pressure transmitter with chemical seal for pressure and level measurement. The chemical seal systems of VEGABAR 81 adapted to the process, ensure a reliable measurement even with highly corrosive and hot products. The simple connection of VEGABAR series 80 sensors as electronic differential pressure opens new possibilities for the measurement of differential pressures.
Benefits
- Simple adaptation thanks to various configuration options
- Reliable measurement with temperatures up to 400 °C
- Reliable measurement independent of foam generation or tank installations
Technical Data
| Measuring range – Distance | – |
| Measuring range – Pressure | -1 … 1000 bar |
| Process temperature | -90 … 400 °C |
| Process pressure | -1 … 1000 bar |
| Accuracy | 0.2 % 0.1 % |
| Materials, wetted parts | Alloy C22 (2.4602) Alloy 400 (2.4360) Tantalum Alloy C276 (2.4819) Duplex (1.4462) Titanium Grade 2 (3.7035) 1.4435 316/316L Titanium Grade 7 (3.7235) |
| Threaded connection | ≥ G½, ≥ ½ NPT |
| Flange connection | ≥ DN25, ≥ 1″ |
| Hygenic fittings | Clamp ≥ 1″ – DIN32676, ISO2852 Slotted nut ≥ 1½”, ≥ DN40 – DIN 11851 hygienic fitting with tension flange DN32 hygienic fitting F40 with compression nut Hygienice flange connection ≥ DN50 DIN11864-2 Hygienic fittings ≥ DN40 – DIN11864-1-A |
| Seal material | no media contact |
| Housing material | Plastic Aluminium Stainless steel (precision casting) Stainless steel (electropolished) |
| Protection rating | IP66/IP68 (0,2 bar) IP66/IP67 IP66/IP68 (1 bar) IP66/IP68 (25 bar) IP69 |
| Output | Profibus PA Foundation Fieldbus 4 … 20 mA Two-wire: 4 … 20 mA/HART Modbus Secondary electronics for electronic differential pressure |
| Ambient temperature | -40 … 80 °C |
| Scope | ATEX / Europe CSA / Canada FM / USA EAC (GOST) / Belarus EAC (GOST) / Kazakhstan EAC (GOST) / Russia IEC / worldwide NEPSI / China UKR Sepro / Ukraine INMETRO / Brazil CCOE / India CSA / USA and Canada |
| Explosion protection | Intrinsic safety “i” Flameproof enclosure “d” Dust ignition protection “t” |
| Foodstuffs/Pharma | FDA EG1935/2004 |
| Ship approval | ABS BV CCS DNV LR RINA |
| Overfill protection | WHG VLAREM II |
| SIL qualification | SIL2 |
| Adjustment | PLICSCOM PC, PACTware and DTM HART-Communicator Software (e. g. AMS™, PDM) |
| Indication | Display/adjustment module PLICSCOM VEGADIS 81 VEGADIS 82 |