Characteristic
Universally applicable pressure transmitter. The ceramic measuring cell is resistant to temperature shocks. Can be combined with any other sensor of VEGABAR Series 80 for electronic differential pressure measurement.
Application
The VEGABAR 82 pressure transmitter can be used universally for the measurement of gases, vapours and liquids. Substances such as sand can be handled easily thanks to the abrasion-resistant ceramic measuring cell. The VEGABAR 82 offers maximum reliability. The transmitter can be used in all industries. The simple connection of VEGABAR series 80 sensors as electronic differential pressure opens new possibilities for the measurement of differential pressures.
Benefits
- Low maintenance costs thanks to wear-free ceramic measuring cell
- High plant availability through maximum overload and vacuum resistance of the ceramic measuring cell
- Measurement down to the last drop through smallest measuring ranges with high accuracy
Technical Data
| Measuring range – Distance | – |
| Measuring range – Pressure | -1 … 100 bar |
| Process temperature | -40 … 150 °C |
| Process pressure | -1 … 100 bar |
| Accuracy | 0.05 % |
| Materials, wetted parts | PVDF 316L Alloy C22 (2.4602) PP 1.4057 1.4410 Alloy C276 (2.4819) Duplex (1.4462) Titanium Grade 2 (3.7035) |
| Threaded connection | ≥ G¼, ≥ ¼ NPT |
| Flange connection | ≥ DN15, ≥ ½” |
| Hygenic fittings | Clamp ≥ 1″ – DIN32676, ISO2852 Slotted nut ≥ DN25 – DIN 11851 hygienic fitting with tension flange DN32 hygienic fitting F40 with compression nut DRD connection ø 65 mm SMS 1145 DN51 SMS DN38 Swagelok VCR screwing Varivent G125 Varivent N50-40 for NEUMO BioControl D50 PN16 / 316L |
| Seal material | EPDM FKM FFKM |
| Housing material | Plastic Aluminium Stainless steel (precision casting) Stainless steel (electropolished) |
| Protection rating | IP66/IP68 (0,2 bar) IP66/IP67 IP66/IP68 (1 bar) IP66/IP68 (25 bar) IP69 |
| Output | Profibus PA Foundation Fieldbus 4 … 20 mA Two-wire: 4 … 20 mA/HART Modbus Secondary electronics for electronic differential pressure |
| Ambient temperature | -40 … 80 °C |
| Scope | ATEX / Europe FM / USA EAC (GOST) / Belarus EAC (GOST) / Kazakhstan EAC (GOST) / Russia IEC / worldwide NEPSI / China UKR Sepro / Ukraine INMETRO / Brazil CCOE / India CSA / USA and Canada IA UKEX |
| Explosion protection | Intrinsic safety “i” Flameproof enclosure “d” Dust ignition protection “t” |
| Foodstuffs/Pharma | 3A EHEDG FDA Drinking water EG1935/2004 |
| Ship approval | ABS BV CCS DNV LR RINA |
| Overfill protection | WHG VLAREM II |
| SIL qualification | SIL2 |
| Adjustment | PLICSCOM PC, PACTware and DTM HART-Communicator Software (e. g. AMS™, PDM) |
| Indication | Display/adjustment module PLICSCOM VEGADIS 81 VEGADIS 82 |