Specs at a glance
-
Accuracy
Standard 0.2%
Optional 0.1% -
Process temperature
PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F -
Pressure measuring range
100 mbar…10 bar
(1.5 psi…150 psi) -
Process pressure / max. overpressure limit
40 bar (600 psi)
-
Main wetted parts
Alloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh -
Max. measurement distance
100 m (328 ft) H2O
-
Material process membrane
316L, AlloyC,
Gold-Rhodium
PE, FEP -
Measuring cell
100 mbar…10 bar
(1.5 psi…150 psi)
Field of application
The Deltapilot FMB52 is a cable version including a fixed process connection. This device with the Contite measuring cell is typically used in the process and environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and is unaffected by possible foam formation. For use in SIL2 safety systems.
For level measurement.
-
Process connections: Threads and flanges
-
Temperature: With PE cable: -10 to +70°C (+14 to +158°F),
with FEP cable: -10 to +80°C (14 to 176°F)
-
Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)
-
Accuracy: ±0.2%, ±0.1% (option)
-
International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval
Benefits
-
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
-
Modular concept for easy replacement of display or electronics
-
Seamless and independent system integration (HART/PA/FF)
-
Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus
-