Key Specifications
-
Maximum measurement error
2% – 10% (depending on measurement range)
-
Operating temperature range
-20…+85°C
(-4…+185°F)
CIP-capable up to 130°C / 266°F -
Maximum process pressure
100 bar (1,740 psi)
Applications
This flow switch enables safe measurement, display, and monitoring of relative mass flow rates in liquid media with minimal pressure drop. Configurable with either one or two switch outputs, or one switch output plus a standardized analog output for flow rate or temperature data. Ideal for applications such as: monitoring cooling water circulation in pumps and heat exchangers, lubrication system supervision, or leak detection in process pipelines.
Designed for monitoring and displaying relative mass flow rates of liquids within 0.03 to 3 m/s (0.1 to 9.84 ft/s). Flowphant T DTT31 model available with threaded or coupling connections.
Typical use cases:
-
Supervising cooling systems for pumps, turbines, compressors, and heat exchangers
-
Pipeline leak detection
-
Pump performance monitoring
-
Lubrication system oversight
-
Beverage industry filtration monitoring
Advantages
-
Negligible pressure loss
-
FieldCare configuration software for fast setup and secure parameter storage
-
Optional secondary switch output or 4-20 mA analog output for temperature or percentage flow rate
-
On-site diagnostics via integrated digital display
-
310° rotatable housing and adjustable display for optimal viewing in any position
-
Certified for marine applications