Specs at a glance
-
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3 -
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
-
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
-
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Field of application
Cubemass DCI is the proven sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics, e.g. in applications like lacquering or surface finishing. Neither high pressure nor alternating flow conditions compromise its accuracy. Equipment manufacturers value Cubemass CDI as compact Coriolis sensor with various communication possibilities.
-
Measuring principle operates independently of physical fluid properties such as viscosity or density
-
Measuring accurately smallest quantities of liquids and gases
Device properties
-
Nominal diameter: DN 1 to 6 (1/24 to 1/4″)
-
Process pressure up to 400 bar (5800 psi)
-
Medium temperature up to +200 °C (+392 °F)
-
Device as compact or remote version
-
Flexible outputs
-
Modbus RS485
Benefits
-
Measuring accurately smallest quantities of liquids and gases
-
Space-saving installation – compact single-tube design
-
Fewer process measuring points – multivariable measurement (flow, density, temperature)
-
Suitable for skids – lightweight sensor
-
High flexibility in system integration – wide range of communication interfaces
-
Fast commissioning – pre-configured devices
-
Automatic recovery of data for servicing