Key Specifications
-
Operating Temperature
-200 °C … 250 °C
(-328 °F … 482 °F) -
Operating Pressure / Maximum Overpressure
Vacuum … 160 bar
(Vacuum … 2320 psi) -
Minimum Medium Conductivity
20 μS/cm
Application
Model 11961Z is a rugged probe designed for aggressive media due to its corrosion-resistant electrode and insulation materials. Suitable for steam boiler applications thanks to its ceramic insulation resistant to steam and hot water exposure.
For level detection in process and storage tanks with conductivity from 0.02mS/cm. Can be used as overflow protection with line monitoring even in Zone 0 hazardous areas, pump protection in pipelines, and two-point control.
-
Connection: Threaded
-
Measuring Range: 100-2000mm (5.9-78.7″)
-
Temperature: -200…+250°C (-328…+482°F)
-
Pressure: -1…+160bar (-15…+2,320psi)
-
Components: FTW325 Transmitter
-
International explosion protection certifications, WHG overflow protection
Advantages
-
Reliable measurements in aggressive media due to corrosion-resistant electrode and insulation materials
-
Suitable for steam boilers thanks to heat-resistant ceramic insulation
-
Operation under high pressure and vacuum conditions
-
Probe length can be adjusted if required