Specs at a glance
Pressure
-
Measuring principle
Absolute and gauge pressure
-
Characteristic
Pressure transmitter with metal membrane for accurate measurement in liquids or gases.
Available with diaphragm seals.
Intuitive and clear wizard for commissioning -
Supply voltage
Ex d, Ex e, non-Ex:
10.5…35V DC
Ex i: 10.5…30V DC -
Reference Accuracy
Standard:
up to 0.075 %
Platinum:
up to 0.055 % -
Long term stability
0.1% of URL/year
0.2% of URL/ 5 years
0.25% of URL/ 10 years -
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-70°C…+400°C
(-x°F…+752°F) -
Ambient temperature
-40°C…+85°C
(-40°F…+185°F) -
Measuring cell
400 mbar…400 bar
(6psi…6,000psi) -
Smallest calibratable span
20 mbar (0.3 psi)
-
Vacuum resistance
50 mbar (0.725 psi)
-
Max. Turn down
100:1
-
Max. overpressure limit
2,800 bar (40,600 psi)
-
Process connection
Thread:
G1/2…G2, R1/2, MNPT3/4…MNPT2,
FNPT1/2
Flange:
DN25…DN80,
NPS 1″…3″ -
Process connection hygienic
Process connection hygienic
-
Material process membrane
316L, AlloyC,
Tantal, Monel,
PTFE -
Material gasket
PTFE
-
Fill fluid
Silicone oil, Inert oil,
Vegetable oil,
High/ low temperature oil -
Material housing
Aluminium
-
Communication
4…20 mA,
4…20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional) -
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI
-
Safety approvals
SIL
-
Design approvals
EN10204-3.1,
NACE MR0175,
NACE MR0103 -
Hygienic approvals
Hygienic approvals
-
Marine approvals
Marine approvals
-
Drinking water approvals
NSF
-
Specialities
Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Continuous / Liquids
-
Measuring principle
Absolute and gauge pressure
-
Characteristic / Application
Pressure transmitter with metal membrane for accurate measurement in liquids or gases.
Available with diaphragm seals.
Intuitive and clear wizard for commissioning -
Specialities
Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities -
Supply / Communication
Ex d, Ex e, non-Ex:
10.5…35V DC
Ex i: 10.5…30V DC -
Accuracy
Standard:
up to 0.075 %
Platinum
up to 0.055 % -
Long term stability
0.1 % of URL/ year
0.2 % of URL/ 5 years
0.25 % of URL/ 10 years -
Ambient temperature
-40°C…+85°C
(-40°F…+185°F) -
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-40°C…+400°C
(-40°F…+752°F) -
Process pressure / max. overpressure limit
700 bar (10,500 psi)
-
Pressure measuring range
400 mbar… 400 bar
(6psi…6,000psi) -
Main wetted parts
316L, AlloyC,
Tantal, Monel,
PTFE -
Process connection
Thread:
G1/2…G2, R1/2, MNPT3/4…MNPT2,
FNPT1/2
Flange:
DN25…DN80,
NPS 1″…3″ -
Max. measurement distance
4000 m (13,123 ft) H2O
-
Communication
4…20 mA,
4…20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional) -
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI
-
Safety approvals
SIL
-
Design approvals
EN 10204-3.1
NACE MR0175,
NACE MR0103,
AD2000 -
Hygienic approvals
Hygienic approvals
-
Marine approval
Marine approval
-
Drinking water approvals
NSF
-
Options
Diaphragm seal
-
Application limits
Measuring cell: Metal welded
If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure: hydrostatic pressure