Characteristic
For measurement of bulk solids at high process temperatures up to +400 °C. A full/empty adjustment is necessary for setup.
Application
The VEGACAL 67 level sensor can be used universally for continuous level measurement of bulk solids at high process temperatures.
Benefits
- Precise measuring results in virtually all bulk solids and high temperature ranges
- High flexibility through shortenable probe
- Long lifetime and low maintenance requirement through robust mechanical construction
Technical Data
| Measuring range – Distance | 40 m |
| Process temperature | -50 … 400 °C |
| Process pressure | -1 … 16 bar |
| Version | Ceramic insulated cable probe Ceramic insulated cable probe with crimping sleeve Ceramic insulated rod probe |
| Materials, wetted parts | 316L Ceramic 316 |
| Threaded connection | ≥ G1½, ≥ 1½ NPT |
| Flange connection | ≥ DN50, ≥ 2″ |
| Seal material | no media contact |
| Housing material | Plastic Aluminium Stainless steel (precision casting) Stainless steel (electropolished) |
| Protection rating | IP66/IP68 (0,2 bar) IP66/IP67 IP66/IP68 (1 bar) |
| Output | Profibus PA Foundation Fieldbus Two-wire: 4 … 20 mA/HART |
| Ambient temperature | -40 … 80 °C |
| Adjustment | PLICSCOM PC, PACTware and DTM HART-Communicator Software (e. g. AMS™, PDM) |
| Indication | Display/adjustment module PLICSCOM VEGADIS 62 VEGADIS 81 VEGADIS 82 |